IPC · 2024 International Plumbing Code
§712 · Slope of horizontal drains
Effective in IPC 2024.
Plain-English explainer
712 sets the slope rule for horizontal sanitary drains: not less than one-quarter inch per foot (¼ in/ft) for nominal pipe sizes of 3 in and smaller, and not less than one-eighth inch per foot (⅛ in/ft) for nominal pipe sizes of 4 in and larger, so solids are carried along with the liquid flow. The drafter cites it whenever a permit lists a building drain or a horizontal branch.
Why inspectors flag this
A 4 in building drain at ⅛ in/ft that drops below the slope table, or a 3 in branch at less than ¼ in/ft, is the canonical 712 failure; the drafter surfaces the rule so the trench grade matches before the inspector walks the rough-in.
As quoted in the code: Horizontal sanitary drains are installed at a uniform slope of not less than one-quarter inch per foot (¼ in/ft) for nominal pipe sizes of 3 in and smaller and not less than one-eighth inch per foot (⅛ in/ft) for nominal pipe sizes of 4 in and larger, so solids are carried along with the liquid flow.
See all codes that cite this trade
Browse the full International Plumbing Code index for one place to read every section the drafter is allowed to quote. See all codes →
See pricing
See every code, every jurisdiction — without the binder.
Trussmark turns job-site photos and voice notes into code-cited permit drafts the inspector can verify on the spot. Pick the plan that fits your shop and we will size the rest with you. Already cited this code in IPC 2024? Drop your email and we'll size the rest of the permit draft for you. See pricing →